Solving Water Ingress in North American Chemical Plants: IP68 Flameproof & PTC Heater Actuator Guide

November 26, 2026
Laatste bedrijfsnieuws over Solving Water Ingress in North American Chemical Plants: IP68 Flameproof & PTC Heater Actuator Guide

In North American chemical and petrochemical facilities, automated valves are frequently installed in open-air process areas. Beyond the presence of flammable gases or combustible dust, outdoor equipment faces heavy rain, high humidity, and sharp day-to-night temperature swings. For explosion-proof electric actuators, preventing both external water ingress and internal condensation while maintaining strict flameproof compliance is a primary engineering challenge.

Two Major Risks in Outdoor Hazardous Areas: Ingress and Condensation

Conventional flameproof (Ex d) electric actuators often struggle to balance explosion protection with environmental sealing. Under continuous outdoor exposure, standard flat-joint housings can experience seal degradation, leading to low ingress protection and moisture intrusion.

Even with a tightly sealed enclosure, rapid ambient temperature drops in coastal or continental North American plants can cause moisture in the air to condense inside the electrical cavity. Left unmanaged, condensation compromises insulation resistance and damages sensitive electronic control boards.

Core Protection Technologies: IP68 Flameproof Joints and PTC Dehumidification

To address moisture-related failures in hazardous locations, modern explosion-proof actuators combine structural sealing, active dehumidification, and circuit-level protection:

  • Round Flameproof Joint & IP68 Sealing: Utilizing a die-cast aluminum alloy casing with a round seam allowance flameproof joint across the motor, electronic, and connection cavities, the design maintains precise Ex d joint gaps and widths to contain internal explosions while achieving an IP68 protection rating.

  • Continuous PTC Dehumidifying Heater: An optional internal PTC heating element can be installed inside the electrical cavity. The heater remains continuously energized—whether the actuator is operating or idle—to prevent condensation in humid climates or areas with wide diurnal temperature variations.

  • Resin-Potted Servo Controller: The internal servo-controller circuit board utilizes industrial-grade components encapsulated in resin plastic packaging, providing enhanced resistance to humidity and mechanical vibration.

Featured Product: DCL-Ex Series Explosion-Proof Electric Actuator

The DCL-Ex series quarter-turn electric actuator is engineered for chemical, oil, and gas applications requiring both North American hazardous-area compliance and outdoor durability.

Key Technical Specifications
  • Hazardous Area Certifications: Certified to CSA Class I, Division 1, Groups C and D T5/T6 and Class I, Zone 1, AEx db IIC T5/T6 Gb, alongside ATEX/IECEx Ex db h IIC T4 Gb and Ex h tb IIIC T135°C Db, covering over 90% of industrial explosive gas atmospheres.

  • Torque & Mounting: Models DCL-Ex05 through DCL-Ex300 offer rated torques from 50Nm to 3000Nm (maximum torque 65Nm to 3900Nm) with an adjustable 0–90° stroke (0–360° for Ex05). Direct-mount ISO5211 flanges (F03–F16) allow 360° mounting at any angle.

  • Control Precision & Environmental Rating: Available in on-off (S2 short-time duty <15 min) and modulating types (4–20mA / 1–5VDC / 2–10VDC, S4 intermittent duty up to 1,200 cycles/hour, basic error ≤±1%, zero-damping electronic brake). Rated for -25°C to +55°C ambient temperatures with high-strength fritted glass lens indicators.

North American Field Installation Notes

For field wiring, the DCL-Ex series is equipped with 2-M20×1.5 or 1/2" NPT explosion-proof conduit entries; installers must fit matching certified explosion-proof cable glands according to the selected cable size to preserve both IP68 and Ex d integrity. All installation, adjustment, and maintenance procedures must be carried out by trained, qualified explosion-proof technicians in strict accordance with the operation manual.